11-2 Configuring the Trigger-Action Feature
LX Series Configuration Guide
The following events can be configured as triggering events (for
example, triggers) for a Rule:
A humidity reading that is equal to, greater than, or less than
a specified threshold.
A temperature reading that is equal to, greater than, or less
than a specified threshold.
The system clock of the LX unit reaches a certain instant of
time.
The system calendar of the LX unit reaches a specified date or
day of the week.
The CTS signal on a specified asynchronous port changing to
high or low.
The DSR/DCD signal on a specified asynchronous port
changing to high to low.
A specified ping host returning a status of Up or Down.
A pattern-match string is received at a specified LX
asynchronous port.
When an LX unit reboots.
The input status on both Power Input A and Power Input B on
both AC and DC versions of the LX-8000 Series.
The combined result of the “AND” and “OR” of multiple
triggers.
In order to use the Trigger-Action Feature, you must first create
actions and triggers. After you have created actions and
triggers, you can associate actions with triggers in rules.
For more information about creating actions, triggers, and rules:
To create a(n)... See
action “To create or modify an action” on page 11-4
trigger “To create or modify a trigger” on page 11-5
rule “To create or modify a rule” on page 11-17